NI-9213E Request for Availability

NI-9213E, Delta-Sigma, 24 Bits, ±78.125 mV, Thermocouple Input Module

Rated 4.8/5 | 17 ratings

Actual item may vary if no part number is provided on quote request.

National Instruments - Temperature Input Devices - NI-9213E
National Instruments - Temperature Input Devices - NI-9213E - Wiring
NI-9213E New
NI-9213E Refurbished

2 Year Warranty Included

Free Ground Shipping

NIST Calibration Available

Request a Quote

Please fill out the form below to send in your quote request and a representative will contact you with a formal quote. View blog post on Model Name vs. Part Numbers

+Add more parts

Avg. Response Time: 15 min

Prefer to send a text message?

Text your name, e-mail, and parts to quote to:   1-919-809-5227

National Instruments NI 9213E Thermocouple Input Module

The National Instruments NI 9213E is a 16-channel thermocouple input module intended for use in industrial automation applications. It has a 36-terminal detachable spring-terminal connector that makes connecting thermocouples simple. The module's 24 bit analog-to-digital converter (ADC) multiplexes and samples each channel after it has passed through a differential filter. The two common terminals (COM) on the module are internally coupled to the isolated ground reference.

It is advised to connect COM to shielded thermocouples and the shield to a common-mode voltage reference. The COM and the shield need to be linked to earth ground when utilizing floating thermocouples or thermocouples close to it. Each channel has an open thermocouple detection (OTD) circuit that detects open thermocouples by means of a current source between the TC+ and TC-terminals.

For offset error compensation, the NI 9213E also incorporates an autozero channel and cold-junction compensation (CJC). The module uses a maximum of 490 mW of power while it is in active mode and just 25 μW when it is in sleep mode. The maximum thermal dissipation in active mode is 840 mW, while in sleep mode, it is 710 mW at 85°C. This temperature measurement module provides accuracy and flexibility with 16 thermocouple channels, 1 internal autozero channel, and 1 internal CJC channel.

With a voltage measuring range of ±78.125 mV, it uses a 24-bit Delta-Sigma ADC in scanning sampling mode. The NI 9213E is compatible with J, K, T, E, N, B, R, and S thermocouple types, spanning NIST temperature ranges. The kind of thermocouple and the measurement mode chosen affect temperature measurement accuracy. The measurement sensitivity in high-resolution mode is less than 0.02 °C for types J, K, T, E, and N, and less than 0.15 °C for types B, R, and S. With type B having a sensitivity of less than 1.2 °C, the sensitivity in high-speed mode varies from <0.25 °C for types J, K, T, and E to <2.8 °C for types R and S.

   
Model Name   
   
NI-9213E   
   
Part   Number(s)   
   
-   
   
Manufacturer   
   
National Instruments   
   
Number of Channels   
   
16 thermocouple channels   
   
ADC Resolution   
   
24 bits   
   
ADC Type   
   
Delta-Sigma   
   
Voltage Measurement Range   
   
±78.125 mV   
   
Temperature Measurement Ranges   
   
Defined by NIST (J, K, T, E, N, B, R, S thermocouple types)   
   
Measurement Accuracy (High-resolution mode)   
   
<0.02 °C (Types J, K, T, E, N), <0.15 °C (Types B, R, S)   
   
Measurement Accuracy (High-speed mode)   
   
<0.25 °C (Types J, K, T, E), <0.35 °C (Type N), <1.2 °C (Type B), <2.8 °C   (Types R, S)   
   
Power Consumption (Active mode)   
   
490 mW max   
   
Power Consumption (Sleep mode)   
   
25 μW max   
   
Thermal Dissipation (Active mode at 85°C)   
   
840 mW max   
   
Thermal Dissipation (Sleep mode at 85°C)   
   
710 mW max   

Associated part numbers for NI-9213E:

National Instruments NI 9213E Frequently Asked Questions 

Question: What connectors are available on the NI-9213E?
Answer: The device has a 36-terminal detachable spring-terminal connector.

Question: How many channels does the NI-9213E have?
Answer: The module has 16 thermocouple channels.

Question: How does the NI-9213E compensate for offset error?
Answer: The NI-9213E includes an autozero channel and cold-junction compensation (CJC) to address offset error.

Delivery:

UPS, FedEX and DHL – Free Ground on all orders

Overnight, Next Day Air or Expedited shipping options available

International delivery available

Same day shipping for in-stock on location

All of our products are covered by our Apex Waves Warranty.

3 Year Warranty - New Surplus Parts

2 Year Warranty - Refurb / Fully Tested Parts

No hassle return policy.

Dedicated customer service team.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

MI-9213E, NI-O213E, NI-9E13E, NI-921RE, NI-9213W
Why Buy From Apex Waves:
Video thumbnail for Apex Waves Unboxing Experience Video